Heating Modes Explained
The SV controllers feature 3 different operating modes that effect demand heating and filtration behaviour (refer table below). These can be adjusted via the setup menu.
| Display | Mode | Description |
|---|---|---|
| NORM | Normal | Normal operation for demand heating and filtration |
| AWAY | Away | Demand heating is DISABLED. Filtration is fixed at 1 hour per day (the keypad will scroll “AWAY MODE” every 60 secs) |
| WEEK | Week | Monday to Thursday: Demand heating is DISABLED, and filtration fixed at 1 hour per day. Friday to Sunday: Normal Operation |
Accessible options in the setup menu
| Menu Item | Setting | Notes |
|---|---|---|
| MODE | Operating Mode | Normal / Away / Week Modes |
| FILT | Hours of filtration per day | 1 to 24 hours |
| F.CYC | Filtration cycle blocks | Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs |
| SNZE | Sleep time menu | |
| 1.SNZ | Sleep timer 1 | [1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End Time |
| 2.SNZ | Sleep timer 2 | [2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End Time |
| R.SET | Reset sleep timers | Reset sleep timers to factory defaults |
| EXIT | Exit sleep time submenu | |
| P.SAV | Power save settings | Off, Low (off-peak filtration), High (off-peak filtration & heating) |
| W.CLN | Automatic sanitise time | Daily run time of automatic sanitise cycle (00:00 - 23:59) |
| D.DIS | Default display mode | Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME) |
| T.OUT | Load time out period | Pump / Blower time out period (10 to 60 minutes) |
| H.PMP | Heat pump operating mode | Auto (heat or cool) / Heat / Cool / Off (heat pump disabled) |
| H.ELE | Heat pump with SV element boost | On = Heat pump + SV element combined for heating Off = Heat pump only |
| EXIT | Exit setup menu |
Important Notes
The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.
A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.